[소식] 국내 최초 도입, SPT : 스마트펄스 테크놀로지(AMARIS RED)
-
1년 전 아마리스 RED의 제조회사인 SCHWIND 사는 각국을 대표하는
8명의 의학자문위원단과 함께 완전히 새로운 레이저 알고리즘을 연구하는 프로젝트를 시작했습니다.

Name Location David T Lin @ Vancouver, Canada Michiel HA Luger @ Utrecht, The Netherlands Diego de Ortueta @ Recklinghausen, Germany Paolo Vinciguerra @ Milano, Italy Shady T Awwad @ Beirut, Lebanon Maria C Arbelaez @ Muscat, Oman Jerry Tan @ Singapore David Sung-Yong Kang @ Seoul, Korea
SCHWIND 사의 개발자들은 각국의 자문위원들과의 꾸준한 연구를 통해 2015년
SPT : Smart Pulse Technology를 완성, 발표했습니다.
David T. Lin, MD, Canada, Paolo Vinciguerra, MD, Italy, Maria C. Arbelaez, MD, Oman, Shady T. Awwad, MD, Lebanon, David Kang, MD, Korea, Michiel H.A. Luger, MD, The Netherlands, Diego de Ortueta, MD, Germany, Jerry Tan, MD, Singapore SmartPulse Technology (SPT) is a new intelligent SCHWIND AMARIS feature perfecting corneal smoothness to optimise short-term clinical outcomes (up to two weeks after surgery). Long-term outcomes remain unchanged and are already documented through numerous existing AMARIS studies. The clinical evaluation of SPT began in May 2014. The effectiveness of this new feature is presented here with the retrospective evaluation of the initial TransPRK outcomes internationally collected among eight SCHWIND reference clinics. Surface treatments seem to be the most adequate test bed to appraise smoothing effects since the stromal surface is not initially assisted by the LASIK flap or the epithelium acting as smoothing agent. This is clinically supported by the fact that visual recovery typically takes longer than with stromal ablations. Moreover, TransPRK was selected, because it requires some 15,000 to 20,000 extra pulses to remove the epithelium, and this may potentially increase residual roughness. According to figure 1, the mean uncorrected distance visual acuity (UDVA) was 20/27 (0.13±0.15 logMAR) one week postoperatively. Among all contributing centres, UDVA ranged from 20/25 (0.10±0.14 logMAR) to 20/36 (0.26±0.16 logMAR). Figure 1: Mean visual acuities in logMAR over time show an UDVA of 20/40 immediately after ablation, continuously improving within the first days, and then stabilizing at 2-week follow-up
study 2015
Multi-Centre Evaluation of TransPRK outcomes with SCHWIND AMARIS using SmartPulse Technology
Introduction
Methods
Visual Outcomes
Metric (1159) Preop (765) Day 0 (695) Day 1 (679) 1-Week (471) 2-Week (538) 1-Month CDVA -0.02 -0.03 UDVA 0.30 0.23 0.13 0.03 0.00
SmartPulse provides excellent results, particularly in the early postoperative stage after surgery. The contributing surgeons reported shorter recovery time of visual acuity, higher levels of postoperative visual quality, and shorter re-epithelialization time using SPT. Moreover, most of their patients commented that, immediately after surgery, they were seeing almost as well as previously with their glasses. The early outcomes are even further remarkable in that they were obtained with surface treatment (in particular TransPRK) where a longer visual recovery is commonly observed in the early postoperative stage (as opposed to LASIK). At one month postoperatively, refractive outcomes with or without SPT are very similar and confirm the stability and quality of outcomes already achieved with AMARIS technology prior to SPT. In summary, SPT meets the requirements set for it. SPT enhances short-term outcomes by reducing residual roughness and improves smoothness of the residual bed without compromising stability of long-term outcomes. Scanning electron microscope (SEM) images at 1000x showing part of the central corneal stroma after TransPRK with AMARIS technology, without SmartPulse (left) and with SmartPulse (right). The image on the right with SmartPulse has a more homogeneous surface. (Included with the kind permission of Dr. David Kang, Eyereum, Korea)
Multi-Centre Evaluation of TransPRK outcomes with SCHWIND AMARIS using SmartPulse Technology
Conclusion
Contributing surgeons
Imprint
Understanding the patient better
Dr. David Kang treated with AMARIS® and SmartPulse SCHWIND AMARIS 1050RS HEALTHCARE INTELLIGENT TECHNOLOGY
BEYOND Inspired by RESPONSIVE
news
Nextech
MDIntelleSys
TearLab
▲ 2015 ASCRS San Diego에서 SCHWIND 사 부스가 발표한 SPT.
강성용 원장님이 직접 받으신 수술 장면과 집도의셨던 최진영 원장님이 실렸습니다.
※ 아이리움안과의 체험동영상은 의료법을 준수하여 로그인 후 시청이 가능합니다.
-
SPT : Smart Pulse Technology의 가장 큰 특징은 빠른 회복과 높은 시력의 질입니다.
아이리움안과의 강성용 원장님은 SPT 레이저의 높은 성능과 빠른 회복 등의 결과를
2015년 아시아-태평양안과학회(APAO 2015)에서 발표하셨습니다.

一步 高峰论坛
INTRODUCTION 介绍
7월 현재, 각 국의 SPT 공동 개발국을 중심으로 아마리스 레드 'SPT' 라식, 라섹 수술이 시행되고 있으며,
대한민국 KFDA의 정식 허가를 통해 이미 안전성을 입증,
아이리움안과가 SPT의 연구 개발 안과로서 최초 도입하게 되어
환자들에게 보다 빠른 회복과 높은 시력의 질을 약속드리게 되었습니다.

-
스마트펄스 테크놀로지(SPT)는 수술 후 잔여 각막 층을 가장 부드럽게 하여
단기간 내 시력을 향상시키는 3차원 입체 레이저 알고리즘입니다.
각막의 실제 곡률에 가장 가깝게 설계해 빠른 시력회복은 물론 시력의 질,
회복 기간과 통증, 고위수차 감소에 획기적인 기술입니다.

라식 · 라섹 수술 시 각막 절삭 프로파일
구분 설명 기존 레이저 2차원 스마트펄스 3차원 입체
8개국의 아마리스 스마트펄스 공식 센터(한국을 비롯해 이탈리아,
독일, 네덜란드, 캐나다, 싱가포르 등 8개국)가
1,000건 이상의 수술로 효과 입증되었습니다.
-
아이리움안과는 아마리스 RED SPT를 통해 더 나은 시력의 질에
또 다시 한 걸음 나아갔습니다.
하지만 레이저가 알아서 하는 수술의 한계를 인정하고
맞춤형 수술 코웨이브(CO-WAVE)와
2015년 APAO 안과학회에서 발표한 초정밀 맞춤형 수술
하이퍼-큐(Hyper-Q)수술 등을 통해
환자의 눈에 맞는 수술로 진정한 시력의 끌어올리는데
주력할 것입니다.
앞으로 아이리움안과의 새로운 도약과 연구를 기대해주세요!
- [SPT의 역사]를 보여주는 안과, 아이리움안과 -

