공지사항 - 아이리움의 새로운 소식을 확인해 보세요.

NOTICE & NEWS

EYEREUM OPHTHALMIC CLINIC

ESCRS 37TH CONGRESS OF THE ESCRS PARIS

OCULUS - PENTACAM Holladay Report

Dr. David Sung Yong Kang Delivers Lectures on PresbyMAX and Plasma KLEx

2025.12.24 1465

Dr. David Sung Yong Kang Delivers Lectures on PresbyMAX and Plasma KLEx at the Schwind User Meeting in Bangkok

At the Schwind User Meeting held in Bangkok, Thailand,

Dr. David Sung Yong Kang of Eyereum Eye Clinic delivered a comprehensive lecture on the PresbyMAX workflow, clinical application, and surgical procedure.

During his presentation, Dr. Kang explained the core principles of PresbyMAX presbyopia correction,

sharing clinical insights on how to maintain negative spherical aberration of the cornea while enhancing near vision.

He emphasized that presbyopia correction surgery is not merely about improving visual acuity,

but requires precise surgical planning that also considers future cataract surgery.

Ideal Ablation Patterns Matched For Acceptable Ablation Depth And Post Op. K's

EYEREUM EYE CLINIC

PresbyMAX®: A universe of possibilities. Customizable presbyopia treatment planning.

MetricValue
Overall OPD
Pupil centered RMS0.03 μm
Ø6.00 mm

Presbyopia and Cataract Surgery after Previous Laser Vision Correction

Dr. Kang also addressed the management of patients who have previously undergone

laser vision correction procedures such as LASIK or LASEK.

He highlighted that when such patients later require presbyopia correction or cataract surgery,

corneal normalization treatments to correct irregular corneal optics should be performed first,

followed by presbyopia-cataract surgery, in order to achieve higher-quality visual outcomes.

These recommendations were supported by actual surgical outcomes and clinical results.

Efficacy Of Both Eyes - Far And Near VA

Binocular VA Distance vs Near at 3 Months Postop

Distance VisionNear Vision J1Near Vision J2Near Vision J3Near Vision J4
20/1610%10%10%0%
20/2061%93%93%0%
20/2587%93%100%93%
20/3253%73%80%33%

Summary Statistics

  • 20/25 & J3: 100%
  • 20/25 & J2: 93%
  • 20/20 & J3: 93%
  • 20/20 & J2: 87%
  • 20/16 & J1: 10%

Live Clinical Experience Shared by an Ophthalmologist Patient

In July, Dr. Kishore Pradhan, an ophthalmologist who personally underwent PresbyMAX surgery performed by Dr. Kang,

attended the meeting in person and shared his firsthand surgical experience and postoperative visual improvement.

His presentation received significant attention from the audience.

My own PresbyMAX treatment – Immediate postop

I really was amazed how clear I could see the dial of my watch!

Banner Text

  • SCHWIND eye-tech-solutions
  • Minimally invasive Maximally smart
  • SCHWIND ATOS with SmartSight lenticule extraction

Plasma KLEx Lecture

In a separate lecture on Plasma KLEx,

Dr. Kang introduced methods to significantly reduce corneal higher-order aberrations

during lenticule extraction procedures such as SMILE,

based on study results published in the Journal of Refractive Surgery.

Reduction of Corneal Higher Order Aberrations after Keratorefractive Lenticule Extraction By Altering Spot/Track Distances with Low Energy Thresholds

David Sung Yong Kang¹, Kangyoon Kim¹, Soyoung Ryu¹, Samuel Arba-Mosquera³, Tae-im Kim²

  • ¹Eyereum Eye Clinic, Seoul, Korea
  • ²Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea
  • ³Schwind Eye-Tech-Solutions GmbH, Kleinostheim, Germany

Financial Disclosure: D. Kang is a consultant for SCHWIND Eye-Tech-Solutions GmbH, OCULUS Optikgeräte GmbH. S. Arba-Mosquera is an employee of SCHWIND eye-tech-solutions GmbH. Other authors have no proprietary or financial interest in the materials presented herein.

AJO 2017; Ji et al. Lower Laser Energy Levels Lead to Better Visual Recovery After Small-Incision Lenticule Extraction

Energy LevelFluence
Energy 20 = 100nJ625mJ/cm²
Energy 21 = 105nJ656mJ/cm²
Energy 22 = 110nJ687mJ/cm²
Energy 23 = 115nJ718mJ/cm²
Energy 24 = 120nJ750mJ/cm²
Energy 25 = 125nJ781mJ/cm²
Energy 26 = 130nJ812mJ/cm²
Energy 27 = 135nJ843mJ/cm²
Energy 28 = 140nJ875mJ/cm²
Energy 29 = 145nJ906mJ/cm²
Energy 30 = 150nJ937mJ/cm²
Energy 31 = 155nJ968mJ/cm²

Market Parameters2022 (USD)2023 (USD)Change (%)
Revenue (bn)~12.5~14.2~13.6
Operating Profit (bn)~2.8~3.1~10.7
Net Income (bn)~1.9~2.2~15.8
Margin (%)~15.2~15.5~2.0

Commitment to Ongoing Research

Eyereum Eye Clinic remains committed to continuous research and innovation

to provide optimal, evidence-based vision correction solutions

for patients both in Korea and internationally.