안내렌즈삽입술 안전성 향상을 위한 아이리움안과의 연구논문이

SCI 학술지 BMC에 등재됐습니다.

Lee et al. BMC Ophthalmology (2018) 18:163 https://doi.org/10.1186/s12886-018-0835-x

BMC Ophthalmology

RESEARCH ARTICLE Open Access

Analysis of pre-operative factors affecting range of optimal vaulting after implantation of 12.6-mm V4c implantable collamer lens in myopic eyes

Hun Lee 1,2, David Sung Yong Kang 3, Jin Young Choi 3, Byoung Jin Ha 3, Eung Kweon Kim 2,4, Kyoung Yul Seo 2 and Tae-im Kim 2*

Abstract

Background: To evaluate clinical factors affecting postoperative vaulting in eyes that had achieved optimal vaulting within the range of 250–750 μm following implantation of 12.6-mm V4c implantable collamer lenses (ICL).

Methods: A total of 236 eyes of 236 patients that had achieved optimal vaulting following implantation of a 12.6-mm V4c ICL were retrospectively analyzed. Associations between postoperative vaulting and age, preoperative anterior chamber depth (ACD), preoperative axial length (AL), preoperative white-to-white diameter, preoperative pupil size, preoperative sulcus-to-sulcus diameter, and preoperative manifest refraction spherical equivalent were investigated using simple regression, stepwise multiple regression, and multinomial logistic regression analyses.

Results: Mean central vaulting at the 6-month follow-up was 519.0 ± 112.8 μm. Variables relevant to postoperative vaulting were, in order of influence, preoperative ACD (β = 0.305, p < 0.001), preoperative pupil size (β = 0.218, p < 0.001), and preoperative AL (β = 0.171, p = 0.006). Low preoperative pupil size was associated with low optimal vaulting (250 to 450 μm), relative to that observed in the mid optimal vaulting group (451 to 550 μm) (odds ratio = 0.532, P = 0.021). Increasing preoperative ACD was associated with high optimal vaulting (551 and 750 μm), relative to that observed the mid optimal vaulting group (odds ratio = 6.340, P = 0.034).

Conclusions: Myopic eyes with greater preoperative ACD, larger pupil size, and longer AL are predisposed to higher postoperative vaulting following 12.6-mm V4c ICL implantation. Therefore, the extremes of these parameters should be considered when choosing V4c ICL size.

Keywords: 12.6-mm V4c implantable collamer lenses, Postoperative vaulting, Preoperative pupil size, Anterior chamber depth, Axial length

이보플러스 아쿠아 ICL 렌즈삽입술에서개인의 눈 조건에

적합한 렌즈사이즈 선택은 안전성과 직결됩니다.


아이리움안과 의료팀의 SCI 연구논문에 따르면

전방깊이와 동공크기가 더 클수록, 안축장이 더 길수록

렌즈와 수정체 사이의 거리인 볼팅(Vaulting)이

높아지는 경향이 나타났습니다.

따라서 안전한 렌즈삽입술을 위해서는 위와 같은

다양한 변수를 모두 고려해 개인에게 알맞은

ICL 렌즈사이즈를 결정하는 것이 중요합니다.


Lee et al. BMC Ophthalmology (2018) 18:163 Page 4 of 6

Table 3 Results of stepwise multiple regression analysis to select variables relevant to central vaulting in 12.6-mm V4c implantable collamer lens implanted eyes with postoperative optimal range of vaulting

VariablesPartial regression coefficient (B)Standardized partial regression coefficient (β)PR²
< 0.0010.144
Preoperative ACD (mm)0.1710.305< 0.001
Preoperative pupil size (mm)0.0380.218< 0.001
Preoperative AL (mm)0.0170.1710.006
Constant-0.784

Variables in the table are ordered according to the strength of the contribution, which was based on the standardized partial regression coefficient (β) ACD anterior chamber depth, AL axial length


Fig. 1 Subgroup analyses according to degree of postoperative vaulting.

Low optimal vaulting, 250 to 450 μm; mid optimal vaulting, 451 to 550; high optimal vaulting, 551 and 750 μm. ACD = anterior chamber depth. Error bars represent range

Preoperative pupil size (mm) by Vaulting Subgroup

SubgroupPreoperative pupil size (mm) Mean/RangeP-value Comparison
Low optimal vaulting~7.0 (Range ~4.7 to ~8.4)
Mid optimal vaulting~7.3 (Range ~5.0 to ~8.4)P = 0.031 (vs Low)
High optimal vaulting~7.4 (Range ~6.4 to ~8.6)P = 0.002 (vs Low)

Preoperative ACD (mm) by Vaulting Subgroup

SubgroupPreoperative ACD (mm) Mean/RangeP-value Comparison
Low optimal vaulting~3.3 (Range ~2.9 to ~3.9)
Mid optimal vaulting~3.4 (Range ~3.0 to ~3.8)
High optimal vaulting~3.5 (Range ~3.1 to ~3.9)P = 0.010 (vs Low)